Upgrade SigNoZ in place
OBaaS 2.1.2 requires ClickHouse 25.12.5 before its new telemetry-store
migrations run. The migrator is a Helm pre-upgrade hook, so a single application
upgrade from an older ClickHouse version can fail before the database is updated.
Follow the two-step ClickHouse and SigNoZ upgrade procedure after applying the required operator and Gateway API CRD updates. That procedure is for installations where data loss is acceptable and does not create backups.
If existing data must be preserved, follow SigNoZ's ClickHouse upgrade and backup guidance
and validate your recovery point before upgrading. Do not select
signozUpgrade.mode=destructive-replace for this in-place upgrade.